Technical regulations do not apply to medical devices: looking for a TR CU for a blood pressure monitor or a support bandage makes no sense. Instead of a declaration there is a registration certificate, and instead of weeks there are months.
Medical devices follow their own rules, and this is the first thing to learn. The technical regulations of the Customs Union do not apply to them: looking for a TR CU for a blood pressure monitor or a support bandage is pointless, because there is none. Instead of a declaration there is a Roszdravnadzor registration certificate, instead of weeks there are months, and instead of a testing laboratory there is a whole chain of technical tests, toxicology, clinical evaluation and state expert review.
What decides is not the appearance or the material, but the purpose that the manufacturer states. A medical device is something intended for prevention, diagnosis, treatment, rehabilitation, monitoring of the state of the body, or restoring its functions.
This creates a paradox that catches sellers: two products that look the same may have a different status.
| Product | Status |
|---|---|
| Bandage “for support after an injury” | Medical device — a therapeutic purpose is stated |
| Belt “for shaping the figure” | Not a medical device — the purpose is domestic |
| Cream “for treating dermatitis” | Goes beyond cosmetics |
| Cream “moisturizing for dry skin” | Cosmetics under TR CU 009/2011 |
| Test strips for measuring glucose | Medical device for diagnostics |
| Massager “for muscle relaxation” | As a rule, a household appliance |
| Device “for physiotherapy” | Medical device |
The class determines the scope of testing, the duration and the cost of the procedure. The classification is based on the degree of risk to the patient and on how invasive the device is.
| Class | Meaning | Examples |
|---|---|---|
| 1 | Low risk | Bandages, cotton wool, accessories with no medical contact |
| 2a | Medium risk | Blood pressure monitors, thermometers, syringes, many consumables |
| 2b | Increased risk | Physiotherapy devices, some types of diagnostic equipment |
| 3 | High risk | Implantable devices, life-support equipment |
You can determine the class yourself, but a mistake here is expensive: a wrong class means a wrong set of studies and the return of the application. The class is determined by the classification rules, taking into account the purpose, the duration of contact with the body and invasiveness.
The registration certificate is a Roszdravnadzor document that gives the right to put the device into circulation on the market. Without it, a medical device cannot be imported for sale, produced or sold. Neither a declaration, nor a certificate, nor a refusal letter replaces it.
You can check someone else's certificate in the open state register of medical devices. You need to look at the same things as in any register:
The list of models is the item that is checked least often and that fails most often: the certificate is valid, but the specific version is not included in it.
The procedure has several stages, and the steps cannot be swapped.
The timeline is the sum of the duration of each stage, and it cannot be predicted exactly: the clinical part for a high-class device may take longer than all the rest together. Plan the market launch of such a product with a horizon of months, not weeks.
Now two routes exist in parallel. National registration gives a certificate valid in Russia. Registration under the unified rules of the Eurasian Union gives a document recognized in the member states.
The choice depends on where you plan to sell. For a company working only on the Russian market, the national procedure is usually simpler. The rules and the terms of transition between the procedures change — this point should be checked on the date of filing, and you should not rely on last year's experience.
The requirements for accompanying information are stricter for medical devices than for ordinary goods, and they are checked closely.
The instruction for use is not an attachment but a part of the device: its content is evaluated during the expert review and must match the registered dossier. A new indication cannot be added to it after registration — this is a change that must be entered in the register.
The platforms treat this category more strictly than any other, because the responsibility here is heavier.
The most frequent mistake of sellers in this niche is to sell a product “for health” with medical wording without having a registration certificate. The product may be completely harmless: the problem is not in the product, but in the stated purpose. What the platforms request in general — in a separate article.
| Mistake | Consequence |
|---|---|
| A TR CU declaration was issued for a medical device | A document of the wrong system; circulation is still illegal |
| Selling before the registration certificate is received, “while the registration is in progress” | Circulation of an unregistered device |
| The registration certificate exists, but the specific model is not in it | This model is not covered |
| The name in the card does not match the register | A block, a claim during a check |
| Therapeutic wording for an ordinary product | The product is requalified as an unregistered medical device |
| The design or indications were changed without a change in the register | The device no longer matches the dossier |
| No instruction for use in Russian | A violation of the requirements for accompanying documents |
If after the check it turns out that there is no medical purpose, the product returns to the ordinary system of technical regulation — and then the starting point will be the analysis of product lists and the choice of the document form. For cosmetics with borderline claims, the analysis of TR CU 009/2011 is useful.
Marketplaces · February 21, 2026
Which cosmetics go by declaration, which by SGR, and what must be on the label.
Marketplaces · July 1, 2026
What the platforms require when you create a product card, and why cards get blocked.
HS code (TN VED) · February 23, 2026
Why the lists matter more than the code, and how to check whether your product falls under the regulation.